Product Description
Typical Properties
| TYPICAL PROPERTIES | UNIT | FUCHS RENOLIN UNISYN CLP | TEST METHOD | |||
| ISO VG | - | 68 | 100 | 150 | 220 | DIN 51 519 |
| Kinematic viscosity at 40°C | mm2/s | 68 | 100 | 150 | 220 | DIN EN ISO 3104 |
| at 100°C | mm2/s | 10.7 | 14.5 | 19.6 | 26.7 | |
| Viscosity index | - | 147 | 150 | 150 | 155 | DIN ISO 2909 |
| Density at 15°C | kg/ m3 | 848 | 851 | 853 | 854 | DIN 51 757 |
| Colour | ASTM | 0.5 | 1.0 | DIN ISO 2049 | ||
| Flashpoint, Cleveland oopen cup | °C | 240 | 250 | 260 | DIN ISO 2592 | |
| Pourpoint | °C | -56 | -53 | -45 | -42 | DIN ISO 3016 |
| Neutralization number | mgKOH/g | 0.6 | DIN 51 558-1 | |||
| Scuffing and scoring test, FZG A/8.3/90 | Failure load stage | >12 | DIN ISO 14635-1 | |||
| Scuffing and scoring test, FZG A/16.6/140 | 12 | |||||
| Micropitting test, FZG-GFT test GT-C/8.3/90 °C Load stage test/ endurance test |
GF class | GFT high | FVA-information sheet no. 54/I-IV | |||
| Micropitting test, FZG-GFT test GT-C/8.3/60 °C Load stage test/ endurance test |
GFT high | |||||
| FE-8 roller bearing test, 7.5/80/80 and 7.5/100/80 | Pass (excellent) | DIN 51 819-3 | ||||
| TYPICAL PROPERTIES | UNIT | FUCHS RENOLIN UNISYN CLP | TEST METHOD | |||
| ISO VG | - | 320 | 460 | 680 | 1000 | DIN 51 519 |
| Kinematic viscosity at 40°C | mm2/s | 320 | 460 | 680 | 1000 | DIN EN ISO 3104 |
| at 100°C | mm2/s | 35.0 | 45.6 | 62.2 | 84.0 | |
| Viscosity index | - | 155 | 160 | 165 | DIN ISO 2909 | |
| Density at 15°C | kg/ m3 | 860 | 861 | 862 | 864 | DIN 51 757 |
| Colour | ASTM | 1.0 | DIN ISO 2049 | |||
| Flashpoint, Cleveland oopen cup | °C | 260 | 300 | DIN ISO 2592 | ||
| Pourpoint | °C | -42 | -39 | -33 | -27 | DIN ISO 3016 |
| Neutralization number | mgKOH/g | 0.6 | 0.55 | DIN 51 558 | ||
| Scuffing and scoring test, FZG A/8.3/90 | Failure load stage | >14 | DIN ISO 14635-1 | |||
| Scuffing and scoring test, FZG A/16.6/140 | >12 | |||||
| Micropitting test, FZG-GFT test GT-C/8.3/90 °C Load stage test/ endurance test |
GF class | GFT high | FVA-information sheet no. 54/I-IV | |||
| Micropitting test, FZG-GFT test GT-C/8.3/60 °C Load stage test/ endurance test |
GFT high | |||||
| FE-8 roller bearing test, 7.5/80/80 and 7.5/100/80 | Pass (excellent) | DIN 51 819-3 | ||||
Contact our sales consultant in area:
Malaysia, Selangor (Klang, Puchong, Shah Alam, Subang), Kuala Lumpur (Sungai Buloh), Negeri Sembilan (Seremban), Melaka, Johor (Johor Bharu, Muar, Batu Pahat), Pahang (Temerloh, Kuantan), Kelantan (Kota Bahru), Terengganu (Kuala Terengganu), Perak (Ipoh), Kedah (Sungai Petani), Perlis, Penang (Bukit Mertajam, Butterworth, Seberang Prai), Sabah (Kota Kinabalu), Sarawak (Kuching), WP Putrajaya, WP Labuan, Indonesia, Singapore, Thailand, Philippines, Vietnam, Laos, Myanmar, Cambodia, Brunei